Sets Description
0 Legacy/Advanced IR Control and Status Registers.
1 Legacy Baud Rate Divisor Register.
2 Advanced IR Control and Status Registers.
3 Version ID and Mapped Control Registers.
4 Transmitter/Receiver/Timer Counter Registers and IR Control Registers.
5 Flow Control and IR Control and Frame Status FIFO Registers.
6 IR Physical Layer Control Registers
7 Remote Control and IR front-end Module Selection Registers.
5.2 Set0-Legacy/Advanced IR Control and Status Registers
Address Offset Register Name
Register Description
0
RBR/TBR Receiver/Transmitter Buffer Registers
1
ICR
Interrupt Control Register
2
ISR/UFR Interrupt Status or IR FIFO Control Register
3
UCR/SSR IR Control or Sets Select Register
4
HCR
Handshake Control Register
5
USR
IR Status Register
6
HSR
Handshake Status Register
7
UDR/ESCR User Defined Register