English
Language : 

W83L517D Datasheet, PDF (32/138 Pages) Winbond – LPC SUPER I/O
W83L517D
(9) Format A Track
Version 0.6
PHASE R/W
Command W
W
W
W
W
W
Execution W
for Each W
Sector
Repeat:
W
W
Result
R
R
R
R
R
R
R
D7 D6 D5 D4 D3 D2 D1 D0
0 MFM 0 0 1 1 0 1
0 0 0 0 0 HDS DS1 DS0
---------------------- N ------------------------
--------------------- SC -----------------------
--------------------- GPL ---------------------
---------------------- D ------------------------
---------------------- C ------------------------
---------------------- H ------------------------
---------------------- R ------------------------
---------------------- N ------------------------
-------------------- ST0 -----------------------
-------------------- ST1 -----------------------
-------------------- ST2 -----------------------
---------------- Undefined -------------------
---------------- Undefined -------------------
---------------- Undefined -------------------
---------------- Undefined -------------------
REMARKS
Command codes
Bytes/Sector
Sectors/Cylinder
Gap 3
Filler Byte
Input Sector Parameters
Status information after
command execution
(10) Recalibrate
PHASE
R/W D7 D6 D5 D4 D3 D2 D1 D0 REMARKS
Command W
W
0 0 0 0 0 1 1 1 Command codes
0 0 0 0 0 0 DS1 DS0
Execution
Head retracted to Track 0
Interrupt
(11) Sense Interrupt Status
PHASE
R/W D7 D6 D5 D4 D3 D2 D1 D0
Command W
00 0 0 1 0 0 0
Result
R
---------------- ST0 -------------------------
R
---------------- PCN -------------------------
REMARKS
Command code
Status information at the end
of each seek operation
(12) Specify
PHASE R/W
Command W
W
W
D7 D6 D5 D4 D3 D2 D1 D0
0 00 0 0 01 1
| ---------SRT ----------- | --------- HUT ---------- |
|------------ HLT ----------------------------------| ND
REMARKS
Command codes
25
Publication Release Date: Apr. 2000
Revision 0.60