English
Language : 

W83L517D Datasheet, PDF (127/138 Pages) Winbond – LPC SUPER I/O
9.9 Logical Device 7 ( GPIO Port 1)
CR30 ( Default 0x00h)
Bit 7 - 1: Reserved.
Bit 0: = 1 GPIO1 port is Activate
= 0 GPIO1 port is inactive.
W83L517D
Version 0.6
CR62, CR 63 (Default 0x00h, 0x00h )
These two registers select the GPIO1 base address [0x100h : 0xFFFh] on 4byte boundary.
IO address : CRF1 base address
IO address + 1 : CRF3 base address
IO address + 2 : CRF4 base address
IO address + 3 : CRF5 base address
CR70 (Default 0x09 if PNPCSV = 0 during POR, default 0x00 otherwise when the port is active)
Bit [7:4]: These bits select IRQ resource for IRQIN1.
Bit [3:0]: These bits select IRQ resource for IRQIN0.
CRF0 (GPIO1 selection register. Default 0xFFh)
When set to a '1', respective GPIO port is programmed as an input port.
When set to a '0', respective GPIO port is programmed as an output port.
CRF1 (GPIO1 data register. Default 0x00h when the port is active)
If a port is programmed to be an output port, then its respective bit can be read/written.
If a port is programmed to be an input port, then its respective bit can only be read.
CRF2 (GP5 inversion register. Default 0x00h when the port is active)
When set to a '1', the incoming/outgoing port value is inverted.
When set to a '0', the incoming/outgoing port value is the same as in data register.
120
Publication Release Date: Apr. 2000
Revision 0.60