English
Language : 

W83L517D Datasheet, PDF (28/138 Pages) Winbond – LPC SUPER I/O
W83L517D
Version 0.6
(3) Read A Track
PHASE
R/W
Command W
W
W
W
W
W
W
W
W
Execution
Result
R
R
R
R
R
R
R
D7 D6 D5 D4 D3 D2 D1 D0
0 MFM 0 0 0 0 1 0
00
0 0 0 HDS DS1 DS0
---------------------- C ------------------------
---------------------- H ------------------------
---------------------- R ------------------------
---------------------- N ------------------------
-------------------- EOT -----------------------
-------------------- GPL -----------------------
-------------------- DTL -----------------------
-------------------- ST0 -----------------------
-------------------- ST1 -----------------------
-------------------- ST2 -----------------------
---------------------- C ------------------------
---------------------- H ------------------------
---------------------- R ------------------------
---------------------- N ------------------------
REMARKS
Command codes
Sector ID information prior
to command execution
Data transfer between the
FDD and system; FDD
reads contents of all
cylinders from index hole to
EOT
Status information after
command execution
Sector ID information after
command execution
(4) Read ID
PHASE
Command
Execution
Result
R/W
W
W
R
R
R
R
R
R
R
D7 D6 D5 D4 D3 D2 D1 D0
0 MFM 0 0 1 0 1 0
00
0 0 0 HDS DS1 DS0
-------------------- ST0 -----------------------
-------------------- ST1 -----------------------
-------------------- ST2 -----------------------
---------------------- C ------------------------
---------------------- H ------------------------
---------------------- R ------------------------
---------------------- N ------------------------
REMARKS
Command codes
The first correct ID
information on the cylinder
is stored in Data Register
Status information after
command execution
Disk status after the
command has been
completed
21
Publication Release Date: Apr. 2000
Revision 0.60