Bit/Field
7:4
3:0
Name
MUX1
MUX0
Type
R/W
R/W
Reset
0x0
0x0
Description
2nd Sample Input Select
The MUX1 field is used during the second sample of a sequence
executed with the sample sequencer. It specifies which of the analog
inputs is sampled for the analog-to-digital conversion.
1st Sample Input Select
The MUX0 field is used during the first sample of a sequence executed
with the sample sequencer. It specifies which of the analog inputs is
sampled for the analog-to-digital conversion.