English
Language : 

Z8F6421PM020SC Datasheet, PDF (48/299 Pages) Zilog, Inc. – High Performance 8-Bit Microcontrollers Z8 Encore-R 64K Series
Z8 Encore!® 64K Series
Z8 Encore!
28
Timer 2 Control 1
T2CTL1 (F17H - Read/Write)
D7 D6 D5 D4 D3 D2 D1 D0
Timer Mode
000 = One-Shot mode
001 = CONTINUOUS mode
010 = COUNTER mode
011 = PWM mode
100 = CAPTURE mode
101 = COMPARE mode
110 = GATED mode
111 = CAPTURE/COMPARE mode
Prescale Value
000 = Divide by 1
001 = Divide by 2
010 = Divide by 4
011 = Divide by 8
100 = Divide by 16
101 = Divide by 32
110 = Divide by 64
111 = Divide by 128
Timer Input/Output Polarity
Operation of this bit is a function of
the current operating mode of the timer
Timer Enable
0 = Timer is disabled
1 = Timer is enabled
Timer 3 High Byte
T3H (F18H - Read/Write)
D7 D6 D5 D4 D3 D2 D1 D0
Timer 3 current count value [15:8]
Timer 3 Low Byte
T3L (F19H - Read/Write)
D7 D6 D5 D4 D3 D2 D1 D0
Timer 3 current count value [7:0]
Timer 3 Reload High Byte
T3RH (F1AH - Read/Write)
D7 D6 D5 D4 D3 D2 D1 D0
Timer 3 reload value [15:8]
Timer 3 Reload Low Byte
T3RL (F1BH - Read/Write)
D7 D6 D5 D4 D3 D2 D1 D0
Timer 3 reload value [7:0]
Timer 3 PWM High Byte
T3PWMH (F1CH - Read/Write)
D7 D6 D5 D4 D3 D2 D1 D0
Timer 3 PWM value [15:8]
Timer 3 PWM Low Byte
T3PWML (F1DH - Read/Write)
D7 D6 D5 D4 D3 D2 D1 D0
Timer 3 PWM value [7:0]
Timer 3 Control 0
T3CTL0 (F1EH - Read/Write)
D7 D6 D5 D4 D3 D2 D1 D0
Reserved
Cascade Timer
0 = Timer 3 Input signal is GPIO pin
1 = Timer 3 Input signal is Timer 2 out
Reserved
Timer 3 Control 1
T3CTL1 (F1FH - Read/Write)
D7 D6 D5 D4 D3 D2 D1 D0
Timer Mode
000 = One-Shot mode
001 = CONTINUOUS mode
010 = COUNTER mode
011 = PWM mode
100 = CAPTURE mode
101 = COMPARE mode
110 = GATED mode
111 = Capture/COMPARE mode
Prescale Value
000 = Divide by 1
001 = Divide by 2
010 = Divide by 4
011 = Divide by 8
100 = Divide by 16
101 = Divide by 32
110 = Divide by 64
111 = Divide by 128
Timer Input/Output Polarity
Operation of this bit is a function of
the current operating mode of the timer
Timer Enable
0 = Timer is disabled
1 = Timer is enabled
PS019915-1005