Z8F6421PM020SC Datasheet, PDF (104/299 Pages) Zilog, Inc. – High Performance 8-Bit Microcontrollers Z8 Encore-R 64K Series
Z8 Encore!® 64K Series
Product Specification
84
3. Write to the Timer Reload High and Low Byte registers to set the Compare value.
4. If desired, enable the timer interrupt and set the timer interrupt priority by writing to
the relevant interrupt registers.
5. Configure the associated GPIO port pin for the Timer Input alternate function.
6. Write to the Timer Control 1 register to enable the timer.
7. Counting begins on the first appropriate transition of the Timer Input signal. No
interrupt is generated by this first edge.
In m/COMPARE mode, the elapsed time from timer start to Capture event can be calcu-
lated using the following equation:
Capture Elapsed Time (s)
=
(---C----a---p----t--u---r---e----V----a---l--u---e----∠------S----t--a---r--t----V----a---l--u---e---)----×-----P---r---e---s--c---a---l-e-
System Clock Frequency (Hz)
Reading the Timer Count Values
The current count value in the timers can be read while counting (enabled). This capability
has no effect on timer operation. When the timer is enabled and the Timer High Byte reg-
ister is read, the contents of the Timer Low Byte register are placed in a holding register. A
subsequent read from the Timer Low Byte register returns the value in the holding register.
This operation allows accurate reads of the full 16-bit timer count value while enabled.
When the timers are not enabled, a read from the Timer Low Byte register returns the
actual value in the counter.
Timer Output Signal Operation
Timer Output is a GPIO Port pin alternate function. Generally, the Timer Output is toggled
every time the counter is reloaded.
Timer Control Register Definitions
Timers 0-2 are available in all packages. Timer 3 is only available in the 64-, 68-, and 80-
pin packages.
Timer 0-3 High and Low Byte Registers
The Timer 0-3 High and Low Byte (TxH and TxL) registers (Tables 38 and 39) contain the
current 16-bit timer count value. When the timer is enabled, a read from TxH causes the
value in TxL to be stored in a temporary holding register. A read from TMRL always
returns this temporary register when the timers are enabled. When the timer is disabled,
reads from the TMRL reads the register directly.
Writing to the Timer High and Low Byte registers while the timer is enabled is not recom-
mended. There are no temporary holding registers available for write operations, so simul-
PS019915-1005
Timers