Z8F6421PM020SC Datasheet, PDF (176/299 Pages) Zilog, Inc. – High Performance 8-Bit Microcontrollers Z8 Encore-R 64K Series
Z8 Encore!® 64K Series
Product Specification
156
NAK—Send NAK
This bit sends a Not Acknowledge condition after the next byte of data has been read from
the I2C slave. Once asserted, it is deasserted after a Not Acknowledge is sent or the IEN
bit is deasserted. If this bit is 1, it cannot be cleared to 0 by writing to the register.
FLUSH—Flush Data
Setting this bit to 1 clears the I2C Data register and sets the TDRE bit to 1. This bit allows
flushing of the I2C Data register when a Not Acknowledge interrupt is received after the
data has been sent to the I2C Data register. Reading this bit always returns 0.
FILTEN—I2C Signal Filter Enable
This bit enables low-pass digital filters on the SDA and SCL input signals. These filters
reject any input pulse with periods less than a full system clock cycle. The filters introduce
a 3-system clock cycle latency on the inputs.
1 = low-pass filters are enabled.
0 = low-pass filters are disabled.
I2C Baud Rate High and Low Byte Registers
The I2C Baud Rate High and Low Byte registers (Tables 72 and 73) combine to form a 16-
bit reload value, BRG[15:0], for the I2C Baud Rate Generator.
When the I2C is disabled, the Baud Rate Generator can function as a basic 16-bit timer
with interrupt on time-out. To configure the Baud Rate Generator as a timer with interrupt
on time-out, complete the following procedure:
1. Disable the I2C by clearing the IEN bit in the I2C Control register to 0.
2. Load the desired 16-bit count value into the I2C Baud Rate High and Low Byte
registers.
3. Enable the Baud Rate Generator timer function and associated interrupt by setting the
BIRQ bit in the I2C Control register to 1.
When configured as a general purpose timer, the interrupt interval is calculated using the
following equation:
Interrupt Interval (s) = System Clock Period (s) ×BRG[15:0] ]
PS019915-1005
I2C Controller