English
Language : 

CP3BT23 Datasheet, PDF (163/260 Pages) Texas Instruments – CP3BT23 Reprogrammable Connectivity Processor with Bluetooth and Dual CAN Interfaces
22.5 MICROWIRE INTERFACE REGISTERS
Software interacts with the Microwire interface by accessing
the Microwire registers. There are three such registers:
Table 67 Microwire Interface Registers
Name
Address
Description
22.5.2 MICROWIRE Control Register (MWCTL1)
The MWCTL1 register is a word-wide, read/write register
used to control the Microwire module. To avoid clock glitch-
es, the MWEN bit must be clear while changing the states
of any other bits in the register. At reset, all non-reserved
bits are cleared. The register format is shown below.
MWDAT
FF F3A0h
Microwire Data
Register
7
6
5
4
3
2
1
0
SCM EIW EIR EIO ECHO MOD MNS MWEN
MWCTL1
FF F3A2h
Microwire Control
Register
15
MWSTAT
FF F3A4h
Microwire Status
Register
SCDV
9
8
SCIDL
22.5.1 Microwire Data Register (MWDAT)
The MWDAT register is a word-wide, read/write register
used to transmit and receive data through the MDODI and
MDIDO pins. The register format is shown below.
MWEN
te 7
0
MWDAT
Figure 88 shows the hardware structure of the register.
le Write
MWDAT
DIN
Obso Read
Shifter
(Low Byte)
Read Buffer
(Low Byte)
Shifter
(High Byte)
Read Buffer
(High Byte)
1
0
MOD
DOUT
MNS
Figure 88. MWDAT Register
DS074
MOD
The Microwire Enable bit controls whether the
Microwire interface module is enabled.
0 – Microwire module disabled.
1 – Microwire module enabled.
Clearing this bit disables the module, clears
the status bits in the Microwire status register
(the BSY, RBF, and OVR bits in MWSTAT),
and places the Microwire interface pins in the
states described below.
Pin
MSK
MWCS
MDIDO
MDODI
State When Disabled
Master – SCIDL Bit
Slave – Input
Input
Master – Input
Slave – TRI-STATE
Master – Known value
Slave – Input
The Master/Slave Select bit controls whether
the CP3BT23 is a master or slave. When
clear, the device operates as a slave. When
set, the device operates as the master.
0 – CP3BT23 is slave.
1 – CP3BT23 is master.
The Mode Select bit controls whether 8- or 16-
bit mode is used. When clear, the device op-
erates in 8-bit mode. When set, the device op-
erates in 16-bit mode. This bit must only be
changed when the module is disabled or idle
(MWSTAT.BSY = 0).
0 – 8-bit mode.
1 – 16-bit mode.
ECHO
The Echo Back bit controls whether the echo
back function is enabled in slave mode. This
bit must be written only when the Microwire in-
terface is idle (MWSTAT.BSY=0). The ECHO
bit is ignored in master mode. The MWDAT
register is valid from the time the register has
been written until the end of the transfer. In the
echo back mode, MDODI is transmitted (ech-
oed back) on MDIDO if the MWDAT register
does not contain any valid data. With the echo
back function disabled, the data held in the
www.national.com
162