English
Language : 

IC61C6416 Datasheet, PDF (73/80 Pages) Integrated Circuit Solution Inc – 64K X 16 HIGH-SPEED CMOS STATIC RAM
HYB18T256324F–[16/20/22]
256-Mbit DDR SGRAM
Electrical Characteristics
4.11
Operating Currents
4.11.1 Operating Current Ratings
(0°C ≤ TC ≤ +85°C, VDD = +2.0 V ± 0.10 V, VDDQ = +2.0 V ± 0.10 V, see Table 1)
Table 41 Operating Current Ratings
Parameter
Symbol –1.6
typ.
Operating Current
IDD0
274
Operating Current
Precharge Power-Down Standby Current
Precharge Floating Standby Current
IDD1
297
IDD2P
99
IDD2F
156
Precharge Quiet Standby Current
IDD2Q
113
Active Power-Down Standy Current
Active Standby Current
IDD3P
99
IDD3N
182
Operating Current Burst Read
IDD4R
474
Operating Current Burst Write
IDD4W 320
Auto-Refresh Current (tRC=min(tRFC))
Auto-Refresh Current at tREFI
IDD5B
430
IDD5D
101
Self Refresh Current
IDD6
11
Operating Current
IDD7
630
1) IDD specifications are tested after the device is properly initialized.
2) Input slew rate = 2 V/ns.
3) Mesured with Output open and On Die termination off.
4) Enables on-chip refresh and address counter.
–2.0
typ.
238
258
86
136
98
86
158
412
278
374
88
11
548
–2.2
typ.
222
241
81
127
92
81
148
385
265
348
83
11
509
Unit Notes
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
1)2)3)
1)2)3)
1)2)3)
1)2)3)
1)2)3)
1)2)3)
1)2)3)
1)2)3)
1)2)3)
1)2)3)
1)2)3)
1)2)3)4)
1)2)3)
4.12
Operating Current Measurement Conditions
(0°C ≤ TC ≤ +85°C, VDD = +2.0V ± 0.10 V, VDDQ = +2.0 V ± 0.10 V, see Table 1)
Table 42 Operating Current Measurement Conditions
Symbol Parameter/Condition
IDD0
Operating Current - One bank, Activate - Precharge
tCK=min(tCK), tRC=min(tRC)
Databus inputs are SWITCHING; Address and control inputs are SWITCHING, CS = HIGH between
valid commands.
IDD1
IDD2P
IDD2F
Operating Current - One bank, Activate - Read - Precharge
One bank is accessed with tCK=min(tCK), tRC=min(tRC), CL = CL(min), Address and control inputs are
SWITCHING;
CS = HIGH between valid commands. Iout=0mA
Precharge Power-Down Standby Current
All banks idle, power-down mode, CKE is LOW, tCK=min(tCK), Data bus inputs are STABLE.
Precharge Floating Standby Current
All banks idle; CS is LOW, CKE is HIGH, tCK=min(tCK); Address and control inputs are SWITCHING;
Data bus input are STABLE.
Data Sheet
73
Rev. 1.11, 04-2005
10292004-DOXT-FS0U