English
Language : 

PXB4219E Datasheet, PDF (260/290 Pages) Infineon Technologies AG – Interworking Element for 8 E1/T1 Lines
IWE8, V3.4
PXB 4219E, PXB 4220E, PXB 4221E
Electrical Characteristics
Table 45 Receive Timing (8-Bit Data Bus, 33 MHz, Multi-PHY) (cont’d)
No. Signal Name DIR Description
Limit Values
Min
Max
tT7 RXDAT[7:0], A<P Input setup to RXCLK
8
-
tT8 RXPTY,
RXSOC,
tT9 RXCLAV
Input hold from RXCLK
1
-
Signal going low impedance 8
-
to RXCLK
tT10
Signal going high impedance 0
-
to RXCLK
tT11
Signal going low impedance 1
-
from RXCLK
tT12
Signal going high impedance 1
-
from RXCLK
1) The frequency should be equal or smaller than the coreclock CLOCK
Unit
ns
ns
ns
ns
ns
ns
9.6.4 IMA Interface
At the IMA interface the IWE8 operates in cycles of 12 system clocks. ATBTC can
become active during cycle #3, the UNCHEC can become active during cycle #9. The
Port number is always active for 6 cycles.
CLOCK
1
ATBTC
2
UNCHEC
3
P N 0 ..2
Totii
Figure 66 Timing of the IMA Interface
Data Sheet
260
2003-01-20