English
Language : 

PXB4219E Datasheet, PDF (215/290 Pages) Infineon Technologies AG – Interworking Element for 8 E1/T1 Lines
IWE8, V3.4
PXB 4219E, PXB 4220E, PXB 4221E
Register Description
7.57
ICRC Synchronization Errors at Clock Recovery Interface (scri)
Destructive read Address 00111H
Reset value: 0000H
15
8
not used
7
0
scri[7:0]
scri
Synchronization Error at the Clock Recovery Interface
This field counts the amount of synchronization errors at the internal
clock recovery interface. In case there are more than 255 errors, the
value is kept
Note: A synchronization error (scri) generates a random number of parity errors (per)
Data Sheet
215