Register Description
7.52
Average Buffer Filling of Port N (avbN)
Read/Write Address 0010CH + N x 32
Reset value: 2000H
15
not used
7
8
avb[13:8]
0
avb[7:0]
avb
Average buffer filling of port N
This field defines the number of bytes ACM should try to keep in the data
buffer of the clock recovery. This value should correspond with the
number of bytes the clock recovery initially stores in the data buffer.