English
Language : 

M16C62_M Datasheet, PDF (335/615 Pages) Renesas Technology Corp – 16-BIT SINGLE-CHIP MICROCOMPUTER M16C FAMILY / M16C/60 SERIES
Timer A
Mitsubishi microcomputers
M16C / 62A Group
SINGLE-CHIP 16-BIT CMOS MICROCOMPUTER
2.2.5 Operation of Timer A (event counter mode, reload type selected)
In event counter mode, choose functions from those listed in Table 2.2.4. Operations of the circled items
are described below. Figure 2.2.12 shows the operation timing, and Figure 2.2.13 shows the set-up
procedure.
Table 2.2.4. Choosed functions
Item
Set-up
Count source
O
Input signal to TAiIN
(counting falling edges)
Input signal to TAiIN
(counting rising edges)
Timer overflow
(TB2/TAj overflow)
Item
Set-up
Pulse output function O No pulses output
Count operation type O
Factor for switching O
between up and
down
Pulses output
Reload type
Free-run type
Content of up/down flag
Input signal to TAiOUT
Note: j = i – 1, but j = 4 when i = 0.
Operation (1) Setting the count start flag to “1” causes the counter to count the falling edges of the count
source.
(2) If an underflow occurs, the content of the reload register is reloaded, and the count continues.
At this time, the timer Ai interrupt request bit goes to “1”.
(3) If switching from an up count to a down count or vice versa while a count is in progress, the
switch takes effect from the next effective edge of the count source.
(4) Setting the count start flag to “0” causes the counter to hold its value and to stop.
(5) If an overflow occurs, the content of the reload register is reloaded, and the count continues.
At this time, the timer Ai interrupt request bit goes to “1”.
n = reload register content
FFFF16
(1) Start count (2) Underflow
n
(3) Switch count
(5) Overflow
000016
Count start flag “1”
“0”
“1”
Up/down flag
“0”
Timer Ai interrupt “1”
request bit
“0”
(4) Stop count
Start count again
Set to “1” by software
Cleared to “0” by
software
Set to “1” by software
Time
Set to “1” by software
Cleared to “0” when interrupt request is accepted, or cleared by software
Figure 2.2.12. Operation timing of event counter mode, reload type selected
2-18