M16C62_M Datasheet, PDF (116/615 Pages) Renesas Technology Corp – 16-BIT SINGLE-CHIP MICROCOMPUTER M16C FAMILY / M16C/60 SERIES
Timers’ functions for three-phase motor control
Mitsubishi microcomputers
M16C / 62A Group
SINGLE-CHIP 16-BIT CMOS MICROCOMPUTER
Three-phase output buffer register 0
b7 b6 b5 b4 b3 b2 b1 b0
Symbol
IDB0
Address
034A16
When reset
0016
Bit Symbol
Bit name
Function
RW
DU0
DUB0
U phase output buffer 0
U phase output buffer 0
Setting in U phase output buffer 0 (Note)
Setting in U phase output buffer 0 (Note)
DV0
V phase output buffer 0 Setting in V phase output buffer 0 (Note)
DVB0 V phase output buffer 0 Setting in V phase output buffer 0 (Note)
DW0
W phase output buffer 0 Setting in W phase output buffer 0 (Note)
DWB0 W phase output buffer 0 Setting in W phase output buffer 0 (Note)
Nothing is assigned.
In an attempt to write to these bits, write “0”. The value, if read, turns out to be “0”.
Note: When executing read instruction of this register, the contents of three-phase shift
register is read out.
Three-phase output buffer register 1
b7 b6 b5 b4 b3 b2 b1 b0
Symbol
IDB1
Address
034B16
When reset
0016
Bit Symbol
DU1
Bit name
U phase output buffer 1
Function
RW
Setting in U phase output buffer 1 (Note)
DUB1 U phase output buffer 1 Setting in U phase output buffer 1 (Note)
DV1
V phase output buffer 1 Setting in V phase output buffer 1 (Note)
DVB1 V phase output buffer 1 Setting in V phase output buffer 1 (Note)
DW1
W phase output buffer 1 Setting in W phase output buffer 1 (Note)
DWB1 W phase output buffer 1 Setting in W phase output buffer 1 (Note)
Nothing is assigned.
In an attempt to write to these bits, write “0”. The value, if read, turns out to be “0”.
Note: When executing read instruction of this register, the contents of three-phase shift
register is read out.
Dead time timer (Note)
b7
b0
Symbol
DTT
Address
034C16
When reset
Indeterminate
Function
Values that can be set R W
Set dead time timer
1 to 255
Note: Use MOV instruction to write to this register.
Timer B2 interrupt occurrences frequency set counter (Note 1, 2, 3)
b3
b0
Symbol
Address
When reset
ICTB2
034D16
Indeterminate
Function
Values that can be set R W
Set occurrence frequency of timer B2
interrupt request
1 to 15
Note 1: In setting 1 to bit 1 (INV01) - the effective interrupt output specification bit - of three-
phase PWM control register 0, do not change the B2 interrupt occurrences frequency
set counter to deal with the timer function for three-phase motor control.
Note 2: Do not write at the timing of an overflow occurrence in timer B2.
Note 3: Use MOV instruction to write to this register.
Figure 1.15.2. Registers related to timers for three-phase motor control