English
Language : 

M30222 Datasheet, PDF (77/237 Pages) Mitsubishi Electric Semiconductor – SINGLE-CHIP 16-BIT CMOS MICROCOMPUTER
deUvnedloepr ment
MITSUBISHI MICROCOMPUTERS
Specifications in this manual are tentative and subject to change
M30222 Group
Rev. G
Timer A
SINGLE-CHIP 16-BIT CMOS MICROCOMPUTER
Timer Ai mode register
(When not using two-phase pulse signal processing)
b7 b6 b5 b4 b3 b2 b1 b0
0
01
Symbol
Address
When reset
TAiMR(i = 2 to 4) 039816 to 039A16
0016
Bit symbol
Bit name
Function
RW
TMOD0
TMOD1
MR0
MR1
b1 b0
Operation mode select bit 0 1 : Event counter mode
Pulse output function
select bit
Count polarity
select bit (Note 2)
0 : Pulse is not output
(TAi OUT pin is a normal port pin)
1 : Pulse is output (Note 1)
(TAi OUT pin is a pulse output pin)
0 : Counts external signal's falling edges
1 : Counts external signal's rising edges
MR2
Up/down switching
cause select bit
0 : Up/down flag's content
1 : TA iOUT pin's input signal (Note 3)
MR3
0 : (Must always be “0” in event counter mode)
TCK0
TCK1
Count operation type
select bit
Two-phase pulse signal
processing operation
select bit (Note 4)(Note 5)
0 : Reload type
1 : Free-run type
0 : Normal processing operation
1 : Multiply-by-4 processing operation
Note 1: The settings of the corresponding port register and port direction register are invalid.
Note 2: This bit is valid when only counting an external signal.
Note 3: Set the corresponding port direction register to “0”.
Note 4: This bit is valid for the timer A3 mode register.
For timer A2 and A4 mode registers, this bit can be “0 ”or “1”.
Note 5: When performing two-phase pulse signal processing, make sure the two-phase pulse
signal processing operation select bit (address 0384 16) is set to “1”. Also, always be
sure to set the event/trigger select bit (addresses 0382 16 and 038316) to “00”.
Timer Ai mode register
(When using two-phase pulse signal processing)
b7 b6 b5 b4 b3 b2 b1 b0
010001
Symbol
Address
When reset
TAiMR(i = 2 to 4) 039816 to 039A16
0016
Bit symbol
TMOD0
TMOD1
MR0
MR1
MR2
MR3
TCK0
TCK1
Bit name
Operation mode select bit
Function
b1 b0
0 1 : Event counter mode
0 (Must always be “0” when using two-phase pulse signal
processing)
0 (Must always be “0” when using two-phase pulse signal
processing)
1 (Must always be “1” when using two-phase pulse signal
processing)
0 (Must always be “0” when using two-phase pulse signal
processing)
Count operation type
select bit
0 : Reload type
1 : Free-run type
Two-phase pulse
processing operation
0 : Normal processing operation
select bit (Note 1)(Note 2) 1 : Multiply-by-4 processing operation
RW
Note1: This bit is valid for Timer A3 mode register.
For Timer A2 and A4 mode registers,this bit can be “0” or“1”.
Note 2: When performing two-phase pulse signal processing, make sure the two-phase
pulse signal processing operation select bit (address 038416) is set to "1".
Always be sure to set the event/trigger select bit (address 038216 ) to "00".
Fig. 1.53. Timer Ai mode register in event counter mode
1-78