Operation when Error Occurs during Reset-Synchronous PWM Mode Operation, and
Operation is Restarted in PWM Mode 1: Figure 10.111 shows an explanatory diagram of the
case where an error occurs in reset-synchronous PWM mode and operation is restarted in PWM
mode 1 after re-setting.
MTU module
output
TIOC3A
1
2
3
4
RESET TOCR TMDR TOER
(RPWM) (1)
5
6
PFC TSTR
(MTU) (1)
7
8
9
10
11
12
Match Error PFC TSTR TMDR TIOR
occurs (PORT) (0) (PWM1) (1 init
0 out)
13
PFC
(MTU)
14
TSTR
(1)
TIOC3B
• Not initialized (TIOC3B)
TIOC3D
• Not initialized (TIOC3D)
Port output
PE8
High-Z
PE9
High-Z
PE11
High-Z
Figure 10.111 Error Occurrence in Reset-Synchronous PWM Mode,
Recovery in PWM Mode 1
1 to 10 are the same as in Figure 10.110.
11. Set PWM mode 1. (MTU positive phase output is low, and negative phase output is high.)
12. Initialize the pins with TIOR. (In PWM mode 1, the TIOC *B side is not initialized.)
13. Set MTU output with the PFC.
14. Operation is restarted by TSTR.
Rev. 2.00, 09/04, page 303 of 720