English
Language : 

HD64F7047F50 Datasheet, PDF (337/766 Pages) Renesas Technology Corp – Old Company Name in Catalogs and Other Documents
Operation when Error Occurs during Phase Counting Mode Operation, and Operation is
Restarted in PWM Mode 2: Figure 10.103 shows an explanatory diagram of the case where an
error occurs in phase counting mode and operation is restarted in PWM mode 2 after re-setting.
MTU module
output
TIOC*A
1
2
RESET TMDR
(PCM)
3
TIOR
(1 init
0 out)
4
PFC
(MTU)
5
TSTR
(1)
6
Match
7
8
9
10 11
Error PFC TSTR TMDR TIOR
occurs (PORT) (0) (PWM2) (1 init
0 out)
12
PFC
(MTU)
13
TSTR
(1)
• Not initialized (cycle register)
TIOC*B
Port output
PEn
High-Z
PEn
High-Z
n=0 to 15
Figure 10.103 Error Occurrence in Phase Counting Mode, Recovery in PWM Mode 2
1 to 9 are the same as in Figure 10.101.
10. Set PWM mode 2.
11. Initialize the pins with TIOR. (In PWM mode 2, the cycle register pins are not initialized.)
12. Set MTU output with the PFC.
13. Operation is restarted by TSTR.
Rev. 2.00, 09/04, page 295 of 720