English
Language : 

HD64F7047F50 Datasheet, PDF (338/766 Pages) Renesas Technology Corp – Old Company Name in Catalogs and Other Documents
Operation when Error Occurs during Phase Counting Mode Operation, and Operation is
Restarted in Phase Counting Mode: Figure 10.104 shows an explanatory diagram of the case
where an error occurs in phase counting mode and operation is restarted in phase counting mode
after re-setting.
MTU module
output
TIOC*A
1
2
RESET TMDR
(PCM)
3
TIOR
(1 init
0 out)
4
PFC
(MTU)
5
TSTR
(1)
6
Match
7
8
9
Error PFC TSTR
occurs (PORT) (0)
10
TMDR
(PCM)
11
TIOR
(1 init
0 out)
12
PFC
(MTU)
13
TSTR
(1)
TIOC*B
Port output
PEn
High-Z
PEn
High-Z
n=0 to 15
Figure 10.104 Error Occurrence in Phase Counting Mode, Recovery in Phase
Counting Mode
1 to 9 are the same as in Figure 10.101.
10. Not necessary when restarting in phase counting mode.
11. Initialize the pins with TIOR.
12. Set MTU output with the PFC.
13. Operation is restarted by TSTR.
Rev. 2.00, 09/04, page 296 of 720