PIC18F66K80 FAMILY
The PIC18F66K80 family devices are error-active if
both error counters are below the error-passive limit of
128. They are error-passive if at least one of the error
counters equals or exceeds 128. They go to bus-off if
the transmit error counter equals or exceeds the bus-
off limit of 256. The devices remain in this state until the
bus-off recovery sequence is finished. The bus-off
recovery sequence consists of 128 occurrences of
11 consecutive recessive bits (see Figure 27-8). Note
that the CAN module, after going bus-off, will recover
back to error-active without any intervention by the
MCU if the bus remains Idle for 128 x 11 bit times. If this
is not desired, the error Interrupt Service Routine
should address this. The current Error mode of the
CAN module can be read by the MCU via the
COMSTAT register.
Additionally, there is an Error State Warning flag bit,
EWARN, which is set if at least one of the error coun-
ters equals or exceeds the error warning limit of 96.
EWARN is reset if both error counters are less than the
error warning limit.
FIGURE 27-8:
ERROR MODES STATE DIAGRAM
Reset
RXERRCNT < 128 or
TXERRCNT < 128
Error-
Active
Error-
Passive
RXERRCNT  128 or
TXERRCNT  128
TXERRCNT > 255
Bus-
Off
128 occurrences of
11 consecutive
“recessive” bits
27.15 CAN Interrupts
The module has several sources of interrupts. Each of
these interrupts can be individually enabled or dis-
abled. The PIR5 register contains interrupt flags. The
PIE5 register contains the enables for the 8 main inter-
rupts. A special set of read-only bits in the CANSTAT
register, the ICODE bits, can be used in combination
with a jump table for efficient handling of interrupts.
All interrupts have one source, with the exception of the
error interrupt and buffer interrupts in Mode 1 and 2. Any
of the error interrupt sources can set the error interrupt
flag. The source of the error interrupt can be determined
by reading the Communication Status register,
COMSTAT. In Mode 1 and 2, there are two interrupt
enable/disable and flag bits – one for all transmit buffers
and the other for all receive buffers.
The interrupts can be broken up into two categories:
receive and transmit interrupts.
The receive related interrupts are:
• Receive Interrupts
• Wake-up Interrupt
• Receiver Overrun Interrupt
• Receiver Warning Interrupt
• Receiver Error-Passive Interrupt
The transmit related interrupts are:
• Transmit Interrupts
• Transmitter Warning Interrupt
• Transmitter Error-Passive Interrupt
• Bus-Off Interrupt