English
Language : 

PIC18F26K80-I Datasheet, PDF (346/622 Pages) Microchip Technology – 28/40/44/64-Pin, Enhanced Flash Microcontrollers with ECAN™ and nanoWatt XLP Technology
PIC18F66K80 FAMILY
22.3.2
EUSARTx ASYNCHRONOUS
RECEIVER
The receiver block diagram is shown in Figure 22-6.
The data is received on the RXx pin and drives the data
recovery block. The data recovery block is actually a
high-speed shifter operating at x16 times the baud rate,
whereas the main receive serial shifter operates at the
bit rate or at FOSC. This mode would typically be used
in RS-232 systems.
To set up an Asynchronous Reception:
1. Initialize the SPBRGHx:SPBRGx registers for
the appropriate baud rate. Set or clear the
BRGH and BRG16 bits, as required, to achieve
the desired baud rate.
2. Enable the asynchronous serial port by clearing
bit, SYNC, and setting bit, SPEN.
3. If interrupts are desired, set enable bit, RCxIE.
4. If 9-bit reception is desired, set bit, RX9.
5. Enable the reception by setting bit, CREN.
6. Flag bit, RCxIF, will be set when reception is
complete and an interrupt will be generated if
enable bit, RCxIE, was set.
7. Read the RCSTAx register to get the 9th bit (if
enabled) and determine if any error occurred
during reception.
8. Read the 8-bit received data by reading the
RCREGx register.
9. If any error occurred, clear the error by clearing
enable bit, CREN.
10. If using interrupts, ensure that the GIE and PEIE
bits (INTCON<7:6>) are set.
22.3.3
SETTING UP 9-BIT MODE WITH
ADDRESS DETECT
This mode would typically be used in RS-485 systems.
To set up an Asynchronous Reception with Address
Detect Enable:
1. Initialize the SPBRGHx:SPBRGx registers for
the appropriate baud rate. Set or clear the
BRGH and BRG16 bits, as required, to achieve
the desired baud rate.
2. Enable the asynchronous serial port by clearing
the SYNC bit and setting the SPEN bit.
3. If interrupts are required, set the RCEN bit and
select the desired priority level with the RCxIP bit.
4. Set the RX9 bit to enable 9-bit reception.
5. Set the ADDEN bit to enable address detect.
6. Enable reception by setting the CREN bit.
7. The RCxIF bit will be set when reception is
complete. The interrupt will be Acknowledged if
the RCxIE and GIE bits are set.
8. Read the RCSTAx register to determine if any
error occurred during reception, as well as read
bit 9 of data (if applicable).
9. Read RCREGx to determine if the device is
being addressed.
10. If any error occurred, clear the CREN bit.
11. If the device has been addressed, clear the
ADDEN bit to allow all received data into the
receive buffer and interrupt the CPU.
FIGURE 22-6:
EUSARTx RECEIVE BLOCK DIAGRAM
BRG16
x64 Baud Rate CLK
SPBRGHx SPBRGx
Baud Rate Generator
CREN
 64
or
 o1r6
4
OERR
FERR
MSb
Stop (8)
RSR Register
7  1
LSb
0 Start
RX9
Pin Buffer
and Control
Data
Recovery
RXx
SPEN
Interrupt
RX9D
RCREGx Register
FIFO
RCxIF
RCxIE
8
Data Bus
DS39977F-page 346