English
Language : 

MC68HC11P2 Datasheet, PDF (89/268 Pages) Motorola, Inc – Microcontrollers
Freescale Semiconductor, Inc.
Serial Communications Interface (SCI)
Transmit operation
• A stop bit, logic one, used to indicate the end of a frame. (A frame
consists of a start bit, a character of eight or nine data bits, and a
stop bit.)
• A break (defined as the transmission or reception of a logic zero
for some multiple number of frames).
Selection of the word length is controlled by the M bit of SCCR1.
5.4 Transmit operation
The SCI transmitter includes a parallel data register (SCDRH/SCDRL)
and a serial shift register. The contents of the shift register can only be
written through the serial data registers. This double buffered operation
allows a character to be shifted out serially while another character is
waiting in the serial data registers to be transferred into the shift register.
The output of the shift register is applied to TXD as long as transmission
is in progress or the transmit enable (TE) bit of serial communication
control register 2 (SCCR2) is set. The block diagram, Figure 5-2, shows
the transmit serial shift register and the buffer logic at the top of the
figure.
5.5 Receive operation
During receive operations, the transmit sequence is reversed. The serial
shift register receives data and transfers it to the parallel receive data
registers (SCDRH/SCDRL) as a complete word. This double buffered
operation allows a character to be shifted in serially while another
character is still in the serial data registers. An advanced data recovery
scheme distinguishes valid data from noise in the serial data stream.
The data input is selectively sampled to detect receive data, and majority
sampling logic determines the value and integrity of each bit.
MC68HC11P2 — Rev 1.0
Serial Communications Interface (SCI)
For More Information On This Product,
Go to: www.freescale.com
Technical Data