1 - CHANNEL DS3/E3 ATM UNI/PPP COMBO IC
TRANSMIT ATM CELL PROCESSOR BLOCK - TRANSMIT USER CELL FILTER # 2 - FILTERED CELL
COUNT - BYTE 2 (ADDRESS = 0X1F6D)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Transmit User Cell Filter # 2 - Filtered Cell Count[23:16]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT NUMBER
NAME
7-0
Transmit User Cell Fil-
ter # 2 - Filtered Cell
Count[23:16]
TYPE
DESCRIPTION
RUR
Transmit User Cell Filter # 2 - Filtered Cell Count[23:16]:
These RESET-upon-READ bit-fields, along with that in the "Transmit
ATM Cell Processor Block - Transmit User Cell Filter # 2 - Filtered Cell
Count - Bytes 3, 1 and 0" register contain a 32-bit expression for the
number of User Cells that have been filtered by Transmit User Cell Fil-
ter # 2 since the last read of this register.
Depending upon the configuration settings within the "Transmit ATM
Cell Processor Block - Transmit User Cell Filter Control - Transmit
User Cell Filter # 2" Register (Address = 0x1F63), these register bits
will be incremented anytime User Cell Filter # 2 performs any of the
following functions.
• Discards an incoming "User Cell".
• Copies (or Replicates) an incoming "User Cell" and routes the
"copy" to the Transmit Cell Extraction Buffer.
• both the above actions.
NOTE: If the number of "filtered cells" reaches the value
"0xFFFFFFFF" then these registers will saturate to and
remain at this value (e.g., it will not overflow to "0x00000000").
412