Power Supply Sequencing
PS Power-On/Off Power Supply Sequencing
The low-power system must operate before the full-power system can function. The low-power and
full-power domains can be powered simultaneously. To achieve minimum current draw and ensure that the
I/Os are 3-stated at power-on, the recommended power-on sequence for the low-power domain (LPD) is
listed. The recommended power-off sequence is the reverse of the power-on sequence.
1. VCC_PSINTLP
2. VCC_PSAUX, VCC_PSADC, and VCC_PSPLL in any order or simultaneously.
3. VCCO_PSIO
To achieve minimum current draw and ensure that the I/Os are 3-stated at power-on, the recommended
power-on sequence for the full-power domain (FPD) is listed. The recommended power-off sequence is
the reverse of the power-on sequence.
1. VCC_PSINTFP and VCC_PSINTFP_DDR driven from the same supply source.
2. VPS_MGTRAVCC and VCC_PSDDR_PLL in any order or simultaneously.
3. VPS_MGTRAVTT and VCCO_PSDDR in any order or simultaneously.
PL Power-On/Off Power Supply Sequencing
The recommended power-on sequence is VCCINT, VCCINT_IO/VCCBRAM, VCCAUX/VCCAUX_IO, and VCCO to
achieve minimum current draw and ensure that the I/Os are 3-stated at power-on. The recommended
power-off sequence is the reverse of the power-on sequence. If VCCINT and VCCINT_IO/VCCBRAM have the
same recommended voltage levels, they can be powered by the same supply and ramped simultaneously.
VCCINT_IO must be connected to VCCBRAM. If VCCAUX/VCCAUX_IO and VCCO have the same recommended
voltage levels, they can be powered by the same supply and ramped simultaneously. VCCAUX and VCCAUX_IO
must be connected together. VCCADC and VREF can be powered at any time and have no power-up
sequencing requirements.
The recommended power-on sequence to achieve minimum current draw for the GTH or GTY transceivers
is VCCINT, VMGTAVCC, VMGTAVTT OR VMGTAVCC, VCCINT, VMGTAVTT. There is no recommended sequencing for
VMGTVCCAUX. Both VMGTAVCC and VCCINT can be ramped simultaneously. The recommended power-off
sequence is the reverse of the power-on sequence to achieve minimum current draw.
If these recommended sequences are not met, current drawn from VMGTAVTT can be higher than
specifications during power-up and power-down.
PS-PL Power Sequencing
The PS and PL power supplies are fully independent. All PS power supplies can be powered before or after
any PL power supplies. The PS and PL power regions are isolated to prevent damage.