English
Language : 

LAN9303MI-AKZE Datasheet, PDF (56/386 Pages) SMSC Corporation – Small Form Factor Three Port 10/100 Managed Ethernet Switch with Dual MII/RMII/Turbo MII
Small Form Factor Three Port 10/100 Managed Ethernet Switch with Dual MII/RMII/Turbo MII
Datasheet
STRAP NAME
autoneg_strap_2
speed_strap_2
duplex_strap_2
BP_EN_strap_2
Table 4.2 Soft-Strap Configuration Strap Definitions (continued)
DESCRIPTION
PIN / DEFAULT
VALUE
Port 2 Auto Negotiation Enable Strap: Configures the 1b
default value of the Auto-Negotiation (PHY_AN) enable bit
in the (x=2) Port x PHY Basic Control Register
(PHY_BASIC_CONTROL_x).
This strap may also affect the default value of the following
register bits (x=2):
„ Speed Select LSB (PHY_SPEED_SEL_LSB) and Duplex
Mode (PHY_DUPLEX) bits of the Port x PHY Basic
Control Register (PHY_BASIC_CONTROL_x)
„ 10BASE-T Full Duplex and 10BASE-T Half Duplex bits of
the Port x PHY Auto-Negotiation Advertisement Register
(PHY_AN_ADV_x)
„ PHY Mode (MODE[2:0]) bits of the Port x PHY Special
Modes Register (PHY_SPECIAL_MODES_x)
Refer to the respective register definition sections for
additional information.
Port 2 Speed Select Strap: This strap affects the default 1b
value of the following register bits (x=2):
„ Speed Select LSB (PHY_SPEED_SEL_LSB) bit of the
Port x PHY Basic Control Register
(PHY_BASIC_CONTROL_x)
„ 10BASE-T Full Duplex bit and 10BASE-T Half Duplex bit
of the Port x PHY Auto-Negotiation Advertisement
Register (PHY_AN_ADV_x)
„ PHY Mode (MODE[2:0]) bits of the Port x PHY Special
Modes Register (PHY_SPECIAL_MODES_x)
Refer to the respective register definition sections for
additional information.
Port 2 Duplex Select Strap: This strap affects the default 1b
value of the following register bits (x=2):
„ Duplex Mode (PHY_DUPLEX) bit of the Port x PHY Basic
Control Register (PHY_BASIC_CONTROL_x)
„ 10BASE-T Full Duplex bit of the Port x PHY Auto-
Negotiation Advertisement Register (PHY_AN_ADV_x)
„ PHY Mode (MODE[2:0]) bits of the Port x PHY Special
Modes Register (PHY_SPECIAL_MODES_x)
Refer to the respective register definition sections for
additional information.
Port 2 Backpressure Enable Strap: Configures the
1b
default value for the Port 2 Backpressure Enable
(BP_EN_2) bit of the Port 2 Manual Flow Control Register
(MANUAL_FC_2).
Revision 1.5 (07-08-11)
56
DATASHEET
SMSC LAN9303M/LAN9303Mi