3;%  (
5HJLVWHU 'HVFULSWLRQ
 'RZQVWUHDP 0D[LPXP /RVW FHOOV '0/267
Read/write Address A4H
Value after reset 0000H
Recommended value 0003H.
DMLOST(15:0) holds the global MLOST threshold (CLP0+1 cells) for the PM data collection in
downstream direction. A PM block with more than MLOST lost cells is considered severely
errored by the data collection algorithm. Accordingly the SECB counter is incremented. If less
or equal MLOST cells are missing the lost cell counters are incremented.
 'RZQVWUHDP 0D[LPXP 0LVLQVHUWHG FHOOV '00,6,16
Read/write Address A5H
Value after reset 0000H
Recommended value 0002H.
DMMISINS(15:0) holds the global MMISINS threshold for the PM data collection in downstream
direction. A PM block with more than MMISINS misinserted cells is considered severely errored
by the data collection algorithm. Accordingly the SECB counter is incremented. If less or equal
MMISINS cells are misinserted the misinserted cell counters are incremented.
 'RZQVWUHDP 0D[LPXP /RVW &/3 FHOOV '0/267
Read/write Address A6H
Value after reset 0000H
Recommended value 0003H.
DMLOST0(15:0) holds the global MLOST0 threshold (CLP0 cells only) for the PM data collection
in downstream direction. A PM block with more than MLOST0 lost cells is considered severely
errored by the data collection algorithm. Accordingly the SECB counter is incremented. If less
or equal MLOST0 cells are missing the lost cell counters are incremented.
 'RZQVWUHDP 0D[LPXP (UURUV '0(55
Read/write Address A7H
Value after reset 0000H
Recommended value 0003H.
DMERR(15:0) holds the global MERR threshold for the PM data collection in downstream
direction. A BR cell carrying a block error result BLER value greater than MERR denotes a
severely errored block. Accordingly the SECB counter is incremented. If BLER is less or equal
MERR the BLER value is added to the error counter ERRC.