The external RAMs for the storage of connection related OAM data are symmetrical in up- and
downstream direction. Also the addressing is symmetrical as the LCI values for forward and
backward connection are identical. Note that according to the standards each ATM connection
is set-up bi-directional, but not necessarily with the same bit rate in both directions.
Both external RAMs are divided into an F4 and an F5 OAM table. Each connection entry has 4
dwords. With the LCI of the cell first the VC-specific table is addressed. Therein an F4 pointer is
contained pointing to a VP-specific entry. There are two cases, both depicted in the circle of
ILJXUH .
.
Connections:
VPCt
VPCi
VCCa
VCCb
16383
16382
16381
:
LCI (VCCa)

F5 entry
16383
16382
16381
:
LCI (VCCb)



F5 entry
F4 pointer:
LCI2(VPCt)
LCI (VPCi)


F4 pointer:
don’t care LCI2=LCI
:
F4 entry
:
:
:
:
:
F4 entry

:

2
1
0
:
:
:
2
1
0
F5 OAM table
F4 OAM table
)LJXUH  3RLQWHU 6WUXFWXUH RI XS DQG GRZQVWUHDP 2$0 7DEOHV
1. A VPC intermediate point
In this case the F5 entry is "don’t care", except some common fields. See e.g. VPCi in
ILJXUH . The VP-specific entry contains the OAM data for the VPC.
2. A terminated VPC decomposed into VCCs
In this case each VCC has an F5 entry with identical F4 pointers pointing all to the same
F4 entry. See e.g. VCCa and VCCb of VPCt in ILJXUH .