English
Language : 

MC9S12NE64_06 Datasheet, PDF (217/554 Pages) Freescale Semiconductor, Inc – Microcontrollers
Memory Map and Register Definition
7.3.2.5 ATD Control Register 4 (ATDCTL4)
This register selects the conversion clock frequency, the length of the second phase of the sample time and
the resolution of the A/D conversion (i.e.: 8-bits or 10-bits). Writes to this register will abort current
conversion sequence but will not start a new sequence.
R
W
Reset
7
SRES8
0
6
SMP1
5
SMP0
4
PRS4
3
PRS3
2
PRS2
0
0
0
0
1
Figure 7-7. ATD Control Register 4 (ATDCTL4)
1
PRS1
0
0
PRS0
1
Read: Anytime
Write: Anytime
Table 7-10. ATDCTL4 Field Descriptions
Field
7
SRES8
6–5
SMP[1:0]
4–0
PRS[4:0]
Description
A/D Resolution Select — This bit selects the resolution of A/D conversion results as either 8 or 10 bits. The
A/D converter has an accuracy of 10 bits; however, if low resolution is required, the conversion can be speeded
up by selecting 8-bit resolution.
0 10-bit resolution
8-bit resolution
Sample Time Select — These two bits select the length of the second phase of the sample time in units of
ATD conversion clock cycles. Note that the ATD conversion clock period is itself a function of the prescaler
value (bits PRS4–0). The sample time consists of two phases. The first phase is two ATD conversion clock
cycles long and transfers the sample quickly (via the buffer amplifier) onto the A/D machine’s storage node.
The second phase attaches the external analog signal directly to the storage node for final charging and high
accuracy. Table 7-11 lists the lengths available for the second sample phase.
ATD Clock Prescaler — These 5 bits are the binary value prescaler value PRS. The ATD conversion clock
frequency is calculated as follows:
ATDclock = [---B[---P-u---R-s----CS----l-+-o----c1----k]---] × 0.5
Note: The maximum ATD conversion clock frequency is half the bus clock. The default (after reset) prescaler
value is 5 which results in a default ATD conversion clock frequency that is bus clock divided by 12.
Table 7-12 illustrates the divide-by operation and the appropriate range of the bus clock.
SMP1
0
0
1
1
Table 7-11. Sample Time Select
SMP0
0
1
0
1
Length of 2nd Phase of Sample Time
2 A/D conversion clock periods
4 A/D conversion clock periods
8 A/D conversion clock periods
16 A/D conversion clock periods
MC9S12NE64 Data Sheet, Rev. 1.1
Freescale Semiconductor
217