LM3S5D91 Datasheet, PDF (1075/1340 Pages) Texas Instruments – Stellaris® LM3S5D91 Microcontroller
Stellaris® LM3S5D91 Microcontroller
Table 20-2. PWM Signals (108BGA) (continued)
Pin Name
Pin Number Pin Mux / Pin Pin Type Buffer Typea Description
Assignment
PWM0
G1
PD0 (1)
O
F3
PJ0 (10)
J1
PG2 (1)
K1
PG0 (2)
L6
PA6 (4)
M9
PF0 (3)
TTL
PWM 0. This signal is controlled by PWM Generator
0.
PWM1
G2
PD1 (1)
O
J2
PG3 (1)
K2
PG1 (2)
M6
PA7 (4)
H12
PF1 (3)
B6
PJ1 (10)
TTL
PWM 1. This signal is controlled by PWM Generator
0.
PWM2
H2
PD2 (3)
O
J11
PF2 (4)
E12
PB0 (2)
C9
PH0 (2)
TTL
PWM 2. This signal is controlled by PWM Generator
1.
PWM3
H1
PD3 (3)
O
J12
PF3 (4)
D12
PB1 (2)
C8
PH1 (2)
TTL
PWM 3. This signal is controlled by PWM Generator
1.
PWM4
A1
PE6 (1)
O
K1
PG0 (4)
M4
PA2 (4)
L6
PA6 (5)
J11
PF2 (2)
G3
PH6 (10)
B11
PE0 (1)
C9
PH0 (9)
TTL
PWM 4. This signal is controlled by PWM Generator
2.
PWM5
B1
PE7 (1)
O
H3
PH7 (10)
K2
PG1 (4)
L4
PA3 (4)
M6
PA7 (5)
J12
PF3 (2)
A12
PE1 (1)
C8
PH1 (9)
TTL
PWM 5. This signal is controlled by PWM Generator
2.
PWM6
L1
PC4 (4)
O
L5
PA4 (4)
L7
PG6 (4)
K3
PG4 (9)
TTL
PWM 6. This signal is controlled by PWM Generator
3.
PWM7
M2
PC6 (4)
O
M5
PA5 (4)
C10
PG7 (4)
M7
PG5 (8)
TTL
PWM 7. This signal is controlled by PWM Generator
3.
a. The TTL designation indicates the pin has TTL-compatible voltage levels.
20.3 Functional Description
20.3.1
PWM Timer
The timer in each PWM generator runs in one of two modes: Count-Down mode or Count-Up/Down
mode. In Count-Down mode, the timer counts from the load value to zero, goes back to the load
value, and continues counting down. In Count-Up/Down mode, the timer counts from zero up to the
load value, back down to zero, back up to the load value, and so on. Generally, Count-Down mode
January 22, 2012
Texas Instruments-Production Data
1075