20.1
■ Can initiate an ADC sample sequence
The control block determines the polarity of the PWM signals and which signals are passed through
to the pins. The output of the PWM generation blocks are managed by the output control block
before being passed to the device pins. The PWM control block has the following options:
■ PWM output enable of each PWM signal
■ Optional output inversion of each PWM signal (polarity control)
■ Optional fault handling for each PWM signal
■ Synchronization of timers in the PWM generator blocks
■ Synchronization of timer/comparator updates across the PWM generator blocks
■ Extended PWM synchronization of timer/comparator updates across the PWM generator blocks
■ Interrupt status summary of the PWM generator blocks
■ Extended PWM fault handling, with multiple fault signals, programmable polarities, and filtering
■ PWM generators can be operated independently or synchronized with other generators
Block Diagram
Figure 20-1 on page 1072 provides the Stellaris PWM module diagram and Figure 20-2 on page 1072
provides a more detailed diagram of a Stellaris PWM generator. The LM3S5D91 controller contains
four generator blocks that generate eight independent PWM signals or four paired PWM signals
with dead-band delays inserted.