EP2SGX60CF780C4N Datasheet, PDF (171/316 Pages) Altera Corporation – Support for numerous single-ended and differential I/O standards
4. DC and Switching
Characteristics
SIIGX51006-4.6
Operating
Conditions
Stratix® II GX devices are offered in both commercial and industrial
grades. Industrial devices are offered in -4 speed grade and commercial
devices are offered in -3 (fastest), -4, and -5 speed grades.
Tables 4–1 through 4–51 provide information on absolute maximum
ratings, recommended operating conditions, DC electrical characteristics,
and other specifications for Stratix II GX devices.
Absolute Maximum Ratings
Table 4–1 contains the absolute maximum ratings for the Stratix II GX
device family.
Table 4–1. Stratix II GX Device Absolute Maximum Ratings Notes (1), (2),(3)
Symbol
Parameter
Conditions
Minimum Maximum Unit
VCCINT
VCCIO
VCCPD
VI
IOUT
TSTG
TJ
Supply voltage
Supply voltage
Supply voltage
DC input voltage (4)
DC output current, per pin
Storage temperature
Junction temperature
With respect to ground
With respect to ground
With respect to ground
No bias
BGA packages under bias
–0.5
–0.5
–0.5
–0.5
–25
–65
–55
1.8
V
4.6
V
4.6
V
4.6
V
40
mA
150
C
125
C
Notes to Table 4–1:
(1) See the Operating Requirements for Altera Devices Data Sheet for more information.
(2) Conditions beyond those listed in Table 4–1 may cause permanent damage to a device. Additionally, device
operation at the absolute maximum ratings for extended periods of time may have adverse affects on the device.
(3) Supply voltage specifications apply to voltage readings taken at the device pins, not at the power supply.
(4) During transitions, the inputs may overshoot to the voltage shown in Table 4–2 based upon the input duty cycle.
The DC case is equivalent to 100% duty cycle. During transitions, the inputs may undershoot to –2.0 V for input
currents less than 100 mA and periods shorter than 20 ns.