W83877ATF
Table: High frequency selected.
TX_FSL4~0
High Frequency
00011
400K Hz
01000
450K Hz
01011
480K Hz
Note that the other non-defined TX_FSL4~0 are reserved.
4.3.9.2 Set7.Reg2 - Remote Infrared Config Register (RIR_CFG)
Reg.
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
RIR_CFG P_PNB SMP_M RXCFS
-
TX_CFS RX_DM TX_MM1 TX_MM0
default Value
0
0
0
0
0
0
0
0
Bit 7:
Bit 6:
Bit 5:
P_PNB: Programming Pulse Number Coding.
Write to 1 causes programming pulse number coding to be selected. The code format is
defined as follows.
(Number of bits) - 1
B7 B6 B5 B4 B3 B2 B1 B0
Bit value
If the bit value is set to 0, then the high pulse will be transmitted/received. If the bit value
is set to 1, then no energy will be transmitted/received.
SMP_M - Sampling mode.
To choose receiver sampling mode.
Write to 0 causes T-period sampling to be used, so that the T-period is programmed
UART baud rate.
Write to 1 causes direct use of programmed baud rate to do over-sampling.
RXCFS - Receiver Carry Frequency Select
Bit 4:
RXCFS
0
1
Reserved, write 0.
Selected Frequency
30K ~ 56K Hz
400K ~ 480K Hz
- 77 -