Infrared Serial Communications Interface Module (IRSCI)
I/O Registers
Table 13-8. SCI Baud Rate Selection
SCR2, SCR1, and SCR0
000
001
010
011
100
101
110
111
Baud Rate Divisor (BD)
1
2
4
8
16
32
64
128
Use this formula to calculate the SCI baud rate:
baud rate = S-----C----I---c---l--o---c---k-----s---o---u---r--c---e--
16 × PD × BD
where:
SCI clock source = fBUS or CGMXCLK
(selected by CKS bit)
PD = prescaler divisor
BD = baud rate divisor
Table 13-9 shows the SCI baud rates that can be generated with a
4.9152-MHz bus clock when fBUS is selected as SCI clock source.