English
Language : 

XRT72L53 Datasheet, PDF (261/467 Pages) Exar Corporation – THREE CHANNEL DS3/E3 FRAMER IC WITH HDLC CONTROLLER
XRT72L53
THREE CHANNEL DS3/E3 FRAMER IC WITH HDLC CONTROLLER
REV. P1.1.8
áç
PRELIMINARY
TxOH_Ind output pin of the XRT72L53 is electrically
connected to the E3_Overhead_Ind whenever the
XRT72L53 pulses the TxOH_Ind output pin "High", it
will also be driving the E3_Overhead_Ind input pin (of
the Terminal Equipment) "High". Whenever the Termi-
nal Equipment detects this pin toggling "High", it
should delay transmission of the very next E3 frame
payload bit by one clock cycle.
The behavior of the signals between the XRT72L53
and the Terminal Equipment for E3 Mode 2 Operation
is illustrated in Figure 103.
FIGURE 103. BEHAVIOR OF THE TERMINAL INTERFACE SIGNALS BETWEEN THE XRT72L53 AND THE TERMINAL
EQUIPMENT (MODE 2 OPERATION)
Terminal Equipment Signals
E3_Clock_In
E3_Data_Out
Tx_Start_of_Frame
E3_Overhead_Ind
Payload[1522] Payload[1523]
FAS, Bit 9
FAS, Bit 8
XRT72L5x Transmit Payload Data I/F Signals
TxInClk
TxSer
Payload[1522] Payload[1523]
TxFrameRef
TxOH_Ind
FAS, Bit 9
FAS, Bit 8
E3 Frame Number N
E3 Frame Number N + 1
Note: TxOH_Ind pulses high for
12 bit periods in order to
denote Overhead Data
(e.g., the FAS pattern
and the A & N bits).
Note: FAS Pattern bits will not be processed by the
Transmit Payload Data Input Interface.
Note: TxFrame pulses high to denote
E3 Frame Boundary.
How to configure the XRT72L53 to operate in this
mode.
1. Set the NibIntf input pin "Low".
2. Set the TimRefSel[1:0] bit-fields (within the
Framer Operating Mode Register) to "01" as
depicted below.
FRAMER OPERATING MODE REGISTER (ADDRESS = 0X00)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT2
BIT 1
BIT 0
Local
Loopback
DS3/E3*
Internal
LOS
Enable
RESET
R/W
R/W
R/W
R/W
0
0
1
0
3. Interface the XRT72L53, to the Terminal Equip-
ment, as illustrated in Figure 102.
5.2.1.3 Mode 3 - The Serial/Local-Timed/
Frame-Master Mode Behavior of the XRT72L53
Interrupt
Enable
Reset
Frame
Format
TimRefSel[1:0]
R/W
R/W
R/W
R/W
1
0
0
1
If the XRT72L53 has been configured to operate in
this mode, then the XRT72L53 will function as fol-
lows.
A. Local-Timed - Uses the TxInClk signal as the
Timing Reference
261