English
Language : 

ISL78226 Datasheet, PDF (80/94 Pages) Intersil Corporation – Cycle-by-cycle peak current limiting
ISL78226
MCU_VDD Undervoltage Fault Flag (0xD4: Bit 5)
The device detected MCU_VDD undervoltage fault.
0XD4 BIT5
0
OK: MCU_VDD is not undervoltage
1
MCU_VDD undervoltage condition detected
DESCRIPTION
FAULT STATUS REGISTER-4 (0XD5)
Definition: Fault Status Register-4 overcurrent and thermal fault status register
Data Length in Bytes: 1
Data Format: Bit Field
Typical: R/W
Protectable: Yes
Default Value: 00h
Units: N/A.
REGISTER NAME
FAULT STATUS REGISTER-4 (0XD5)
Format
Bit Field
Bit Position
7
6
5
4
3
2
1
0
Access
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Function
Thermal
Protection
Reserved
ACP Fault
CCL
Operation
Reserved NOC at PWMx OC2 Fault at OC1 at PWMx
PWMx
Default Value
0
0
0
0
0
0
0
0
OC1 Flag (0xD5: Bit 0)
Indicates whether cycle-by-cycle Overcurrent 1 condition is detected or not.
When this flag is altered, OC1 has occurred and the phase location can be obtained by reading Fault Status Register-10 (0xD9).
0XD5 BIT0
DESCRIPTION
0
OK: OC1 is not detected.
1
OC1 is detected at PWMx.
OC2 Fault Flag (0xD5: Bit 1)
Indicates whether cycle-by-cycle Overcurrent 2 (OC2) condition is detected or not.
When this flag is altered, OC2 has occurred and the phase location can be obtained by reading Fault Status Register-11 (0xDA).
0XD5 BIT1
DESCRIPTION
0
OK: OC2 is not detected.
1
OC2 is detected at PWMx.
Submit Document Feedback 80
FN8887.0