ISL78226 Datasheet, PDF (69/94 Pages) Intersil Corporation – Cycle-by-cycle peak current limiting
ISL78226
Phase-6 PWM Operation Enable/Disable Control Bit (0xBC: Bit 5)
Disable (remove) Phase-6 PWM operation when desired.
BIT1
0
Enable PWM operation of Phase-6 (default)
1
Disable (remove) Phase-6
DESCRIPTION
V6/V12 Overvoltage/Undervoltage Detection Enable/Disable Control Bit (0xBC: Bit 7)
Selects to enable or disable the V6/V12 overvoltage and undervoltage detection.
BIT0
0
Enable V6/V12 OV/UV detection (default)
1
Disable V6/V12 OV/UV detection
DESCRIPTION
SERIOUS FAULT RESPONSE CONTROL REGISTER (0XBD)
Definition: Serious fault response control register
Data Length in Bytes: 1
Data Format: Bit Field
Typical: R/W
Protectable: Yes
Default Value: 00h
Units: N/A
REGISTER NAME
Format
Bit Position
Access
Function
SERIOUS FAULT RESPONSE CONTROL REGISTER (0XBD)
Bit Field
7
6
5
4
3
2
1
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Boost Mode Buck Mode
BAT48 Short BAT48 Short
to GND Fault to GND Fault
Response Response
Control
Control
Boost Mode
L/S FET
Short Fault
Response
Control
Buck Mode
L/S FET
Short Fault
Response
Control
Reserved
Buck Mode Boost Mode
BAT12 Short H/S FET
to GND Fault Short Fault
Response Response
Control
Control
Buck Mode
H/S FET
Short Fault
Response
Control
Default Value
0
0
0
0
0
0
0
0
NOTE: The ISL78226 detects potential serious fault conditions, such as external power MOSFET shorts, by monitoring the input/output voltages and
continuous overcurrent situations. If a potential serious fault has been detected, the ISL78226 stops the PWMx outputs, which stop the converter, pull
down the "XSYS_FAIL" pin, and turn off the system immediately by using the external shutdown circuit. Even with this fault detection, however, there will
be a delay of a few switching cycles as the fault conditions are being determined. Therefore, this function is recommended for use as a supplemental
fault detector rather than a primary fault detector.
Buck Mode High-Side MOSFET Short Fault Response Control Bit (0xBD: Bit 0)
Set the XSYS_FAIL function when detecting the potential short of H/S MOSFET in Buck mode operation.
BIT0
DESCRIPTION
0
Pull down XSYS_FAIL when the potential H/S MOSFET short is detected in Buck mode (default).
PWM switching will stop immediately and latched-off. To restart, toggle EN or PWM_EN.
1
Do not pull down XSYS_FAIL when the potential H/S MOSFET short is detected in Buck mode.
PWM switching shut off or keep running will depend on the related fault (OC2, BAT12 UV) response settings.
Boost Mode High-Side MOSFET Short Fault Response Control Bit (0xBD: Bit 1)
Set the XSYS_FAIL function when detecting the potential short of H/S MOSFET in Boost mode operation.
BIT0
DESCRIPTION
0
Pull down XSYS_FAIL when the potential H/S MOSFET short is detected in Boost mode (default).
PWM switching will stop immediately and latched-off. To restart, toggle EN or PWM_EN.
1
Do not pull down XSYS_FAIL when the potential H/S MOSFET short is detected in Buck mode.
PWM switching shut off or keep running will depend on the related fault (OC2, BAT48 UV, BAT12 OV) response settings.
Submit Document Feedback 69
FN8887.0