English
Language : 

ISL78226 Datasheet, PDF (54/94 Pages) Intersil Corporation – Cycle-by-cycle peak current limiting
ISL78226
BAT48 Input Overvoltage Fault (Warning) Control Bit (0xB2: Bit 5:4)
When the individual fault response enable/disable control bit (0xB0[7]) is “1”, the device selects the fault response when BAT48 input
voltage exceeds the first level of overvoltage threshold. When the individual fault response enable/disable control bit (0xB0[7]) is “0”,
the “MODE” pin setting will be used for the fault control and this register setting will be ignored.
BIT1
BIT0
DESCRIPTION
0
0
Flagging only (Default)
When BAT48 input voltage exceeds the first overvoltage threshold, the corresponding fault status register (0xD2[6])
will be set to “1”, and XALERT will be pulled low. The system continues to operate. No hiccup or latch-off responses.
0
1
Hiccup (Auto Restart)
When BAT48 input voltage exceeds the first overvoltage threshold, the corresponding fault status register (0xD2[6])
will be set to “1”, and XALERT will be pulled low. At the same time, the system stops PWM switching. The PWM
switching will recover automatically 500ms (typical) after the overvoltage condition is removed.
1
0
Latch-off
When BAT48 input voltage exceeds the first overvoltage threshold, the corresponding fault status register (0xD2[6])
will be set to “1”, and XALERT will be pulled low. At the same time, the system stops PWM switching. The PWM
switching will not recover automatically when the overvoltage condition is removed. To recover the switching, toggle
PWM_EN or EN.
1
1
Flagging only (same as “0.0”)
BAT48 Input Undervoltage Fault (Warning) Control Bit (0xB2: Bit 7:6)
When the individual fault response enable/disable control bit (0xB0[7]) is “1”, the device selects the fault response when BAT48
becomes lower than the first level of undervoltage threshold. When the individual fault response enable/disable control bit (0xB0[7]) is
“0”, the “MODE” pin setting will be used for the fault control and this register setting will be ignored.
BIT1
BIT0
DESCRIPTION
0
0
Flagging only (Default)
When BAT48 input voltage becomes lower than the first undervoltage threshold, the corresponding fault status
register (0xD2[7]) will be set to “1”, and XALERT will be pulled low. The system continues to operate. No hiccup or
latch-off responses.
0
1
Hiccup (Auto Restart)
When BAT48 input voltage becomes lower than the first undervoltage threshold, the corresponding fault status
register (0xD2[3]) will be set to “1”, and XALERT will be pulled low. At the same time, the system stops PWM
switching. The PWM switching will recover automatically 500ms (typical) after the undervoltage condition is
removed.
1
0
Latch-off
When BAT48 input voltage becomes lower than the first undervoltage threshold, the corresponding fault status
register (0xD2[7]) will be set to “1”, and XALERT will be pulled low. At the same time, the system stops PWM
switching. The PWM switching will not recover automatically when the undervoltage condition is removed. To recover
the switching, toggle PWM_EN or EN.
1
1
Flagging only (same as “0,0”)
Submit Document Feedback 54
FN8887.0
November 7, 2016