English
Language : 

I347-AT4 Datasheet, PDF (137/148 Pages) Intel Corporation – Intel® Ethernet Network Connection I347-AT4 Datasheet
Thermal Design Recommendations — I347-AT4
7.6
Package Thermal/Mechanical Specifications and Limits
7.6.1
Thermal Limits - Max Junction/Case
To ensure proper operation of the I347-AT4, the thermal solution must dissipate the heat generated by
the component and maintain a case temperature at or below the values listed in Table 7.1. Table 7.2
lists the thermal performance parameters per JEDEC JESD51-2 standard.
The I347-AT4 is designed to operate properly as long as the Tcase rating is not exceeded. Section 7.10.1
describes the proper guidelines for measuring the case temperature.
Table 7.1. Absolute Maximum Junction/Case Temperature
Application
Measured TDP (W)
Tcase-max (°C)1
I347-AT4
3.0 W @ 125 °C Tj-max
108.11
1. Max Tcase is based on 27 x 27 x 10 mm Thermalloy heat sink as shown in Figure 7.3.
The thermal limits previously defined are based on simulated results of the package assembled on a
standard multi-layer, 2s2p board with 1 oz internal planes and 2 oz external trace layers in a forced
convection environment. The maximum case temperature is based on the maximum junction
temperature and defined by the relationship, Tcase-max = Tj-max – (ΨJT * PTDP) where ΨJT is the
junction-to-top (of package) thermal characterization parameter. If the case temperature exceeds the
specified Tcase-max, thermal enhancements such as heat sinks or forced air are required.
Analysis indicates that real applications are unlikely to cause the I347-AT4 to be at Tcase-max for
sustained periods of time, given a properly designed thermal solution. Sustained operation at Tcase-max
might affect long-term reliability of the I347-AT4 and the system and thus should be avoided.
127