English
Language : 

PXF4333 Datasheet, PDF (208/361 Pages) Infineon Technologies AG – ABM 3G ATM Buf fer Manager
EPDen
PPDen
SCNT
GFRen
ABM-3G
PXF 4333 V1.1
Register Description
4d
THi >>5
TLi:= 248
5d
THi >>6
TLi:= 252
6d
THi >>7
TLi:= 254
7d
THi >>8
(hysteresis ineffective) TLi:= 256
EPD for the individual traffic class. EPD is used for every
connection (LCI) within that traffic class (see Chapter 3.4.1.6.3):
0
EPD is disabled.
1
EPD is enabled.
PPD for the individual traffic class. PPD is used for every
connection (LCI) within that traffic class (see Chapter 3.4.1.6.3):
0
PPD is disabled
1
PPD is enabled
Counter Function Select
This bit selects the function of counter ’AcceptedCells/
Packets(31:0)’:
0
Accepted Packets are counted
1
Accepted Cells are counted
GFR Enable:
This bit enables a modified EPD threshold evaluation for GFR traffic
(see Chapter 3.4.1.6.3).
0
Modified EPD threshold evaluation for GFR disabled
1
Modified EPD threshold evaluation for GFR enabled
Register WAR.Word64Sel(1:0) =’01’:
Bit
15
14
13
12
11
10
9
8
TrafClassMax(7:0)
Data Sheet
208