English
Language : 

DS616 Datasheet, PDF (48/60 Pages) Xilinx, Inc – LogiCORE IP PLBV46 PCI Full
LogiCORE IP PLBV46 PCI Full Bridge (v1.04.a)
Data is loaded in the Configuration Address Port with the Byte format specified in the PCI 2.2. specification. A
PLB-side read of the Configuration Data Port initiates a Configuration Read command with data returned to the
PLB-side upon completion of the PCI-side read command. A PLB-side write to the Configuration Data Port register
initiates a Configuration Write transaction on the PCI bus. Determination of whether the read or write transfer is
type 0 or type 1 is done automatically.
Both type 0 and type 1 configuration transactions are supported. The type of transaction is determined from the Bus
number in the Configuration Address Port register (Bits 8-15) and the bus numbers in the Bus
Number/Subordinate Bus Number register. The local bus number is located at bits 8-15 and the maximum
subordinate bus number is located at bits 24-31 in the Bus Number/Subordinate Bus Number register. If the Bus
number in the Configuration Address Port register is equal to the local bus number in the Bus
Number/Subordinate Bus Number register (bits 8-15), a type 0 transaction is performed. If the Bus number in the
Configuration Address Port register is greater than the bus number in the Bus Number/Subordinate Bus Number
register and less than or equal to the maximum subordinate Bus number, a type 1 transaction is performed. If a
configuration transaction to a Bus Number not satisfying the inequality relation is attempted, then PLB Sl_MErr is
asserted. When a configuration read from a bus number not in the subordinate bus range is initiated, nothing occurs
on the PCI bus and the PLB Sl_MErr signal is asserted. When a configuration write to a bus number not in the
subordinate bus range is initiated, nothing occurs on the PCI bus, the data is discarded and PLB Sl_MErr is asserted.
These conditions are equivalent to the situation where the master enable bit in the configuration command register
of the PCI32 core is not set.
If a configuration read to a device number not assigned to a device on the PCI bus is attempted, a Master Abort
occurs on the PCI bus, and all ones are returned on the PLB bus.
IDSEL is asserted for the device to be configured in all type 0 configuration transactions. The most common
implementation method for IDSEL is used in this bridge implementation where address lines AD[31:16] are
required to be mapped to IDSEL for each device.
The mapping is:.
• IDSEL of device 0 is connected to AD16
• IDSEL of device 1 is connected to AD17
• IDSEL of device 2 is connected to AD18.
• ...
• IDSEL of device 15 is connected to AD31
A decode of the device number in the Configuration Address Port is used to determine which address line/IDSEL
is asserted.
As noted, when the bridge has host bridge configuration functionality, IDSEL of the PCI32 core is connected
internally to the AD-bit specified by the C_BRIDGE_IDSEL_ADDR_BIT parameter.
C_NUM_IDSEL specifies the number of PCI agents that can be configured on the PCI bus by specifying the number
of IDSEL lines that are decoded and assigned to address lines AD[31:16]. Each device on the bus must have its
IDSEL line properly connected to the PCI AD bus. It can be resistively-coupled to the associated address bit or
direct coupling, if it is not detrimental to performance per PCI 2.2 specification. Because the PCI32 core does not
support address stepping, resistive coupling of IDSEL with the assigned address bit must be sufficient to ensure
proper signal levels at IDSEL without utilizing address stepping.
DS616 June 22, 2011
www.xilinx.com
48
Product Specification