English
Language : 

DS616 Datasheet, PDF (30/60 Pages) Xilinx, Inc – LogiCORE IP PLBV46 PCI Full
LogiCORE IP PLBV46 PCI Full Bridge (v1.04.a)
Table 14: Configuration Address Port Register Bit Definitions (Bit assignment assumes 32-bit bus)
Bit(s)
Name
Access Reset Value
Description
0-5
D0-D5
Read/Write
0x0
Identifies the target word address (32bits) within the function’s
configuration space (1-64)
6-7
D6-D7
Read
0x0
Hard-wired to 0, read-only
8-12
D8-D12
Read/Write
0x0
Identifies the target PCI Device (0-31)
13-15
D13-D15
Read/Write
0x0
Identifies the target function (1-8)
16-23
D16-D23
Read/Write
0x0
Identifies the target PCI Bus (1-256)
24
D24
Read/Write
0x0
Active high enable bit
25-31
D25-D31
Read
0x0
Reserved and hardwired to 0.
Configuration Data Port Register Description
The Configuration Data Port Register exists only if the bridge is configured with PCI host bridge configuration
functionality, such as C_INCLUDE_PCI_CONFIG=1. This register is read/write and definition of this register follows
PCI 2.2. All accesses to the register are 32-bit accesses. A read initiates a configuration read command and a write
initiates a configuration write command. Determination of whether the command is a type 0 or type 1 depends on
the comparison results of the bus number compare. The fields are defined in Table 15. Reset clears all bits. Byte
address integrity is maintained from PCI little endian word format when writing/reading data to/from the
Configuration Data Port register which is defined in big endian word format.
Table 15: Configuration Data Port Address Register Bit Definitions (Bit Assignment Assumes 32-bit Bus)
Bit(s)
Name
Access
Reset
Value
Description
0-31
D0 - D31 Read/Write
0x0 Read or write causes automatic execution of Configuration Read
Command or Configuration Write Command using address/bus
information in the Configuration Address Port register.
Bus Number/Subordinate Bus Number Register Description
The Bus Number/Subordinate Bus Number Register exists only if the bridge is configured with PCI host bridge
configuration functionality, such as C_INCLUDE_PCI_CONFIG=1. This register is read/write. All accesses to the
register are 32-bit accesses. The bus number is an 8-bit value defining the primary bus number. The highest
subordinate bus number is also an 8-bit value. The fields are defined in Table 16. Reset clears all bits.
Table 16: Bus Number/Subordinate Bus Number Register Bit Definitions (Bit Assignment Assumes 32-bit
Bus)
Bit(s)
Name
Access
Reset
Value
Description
0-7
D0- D7
Read
0x0 Reserved
8-15
D8 - D15
Read/Write
0x0 Bus number
16-23
D16 - D23
Read
0x0 Reserved
24-31
D24 - D31
Read/Write
0x0 Maximum subordinate bus number
DS616 June 22, 2011
www.xilinx.com
30
Product Specification