English
Language : 

SM320C6414-EP_16 Datasheet, PDF (59/93 Pages) Texas Instruments – FIXED-POINT DIGITAL SIGNAL PROCESSORS
www.ti.com
SM320C6414-EP, SM320C6415-EP, SM320C6416-EP
FIXED-POINT DIGITAL SIGNAL PROCESSORS
SGUS043D – MAY 2003 – REVISED SEPTEMBER 2008
NO.
PARAMETER
8 td(EKOxH-ADSV) Delay time, ECLKOUTx high to SADS/SRE valid
9 td(EKOxH-OEV) Delay time, ECLKOUTx high to, SOE validE
10 td(EKOxH-EDV) Delay time, ECLKOUTx high to EDx valid
11 td(EKOxH-EDIV) Delay time, ECLKOUTx high to EDx invalidE
12 td(EKOxH-WEV) Delay time, ECLKOUTx high to SWE valid
–50xEP
MIN MAX
1.3
6.4
1.3
6.4
6.4
1.3
1.3
6.4
UNIT
ns
ns
ns
ns
ns
5.3.3 Timing Requirements for Programmable Synchronous Interface Cycles for EMIFB
Module (1) (see Figure 5-13)
NO.
PARAMETER
–50xEP
MIN MAX
UNIT
6
tsu(EDV-EKOxH) Setup time, read EDx valid before ECLKOUTx high
7 th(EKOxH-EDV) Hold time, read EDx valid after ECLKOUTx high
3.1
ns
1.5
ns
(1) These C64x devices have two EMIFs (EMIFA and EMIFB). All EMIFA signals are prefixed by an A and all EMIFB signals are prefixed by
a B. Throughout the rest of this document, in generic EMIF areas of discussion, the prefix A or B may be omitted [e.g., the
programmable synchronous interface access signals are shown as generic (SADS/SRE, SOE, and SWE) instead of ASADS/ASRE,
ASOE, and ASWE (for EMIFA) and BSADS/BSRE, BSOE, and BSWE (for EMIFB)].
NO.
PARAMETER
1 td(EKOxH-CEV) Delay time, ECLKOUTx high to CEx valid
2 td(EKOxH-BEV) Delay time, ECLKOUTx high to BEx valid
3 td(EKOxH-BEIV) Delay time, ECLKOUTx high to BEx invalidE
4 td(EKOxH-EAV) Delay time, ECLKOUTx high to EAx valid
5 td(EKOxH-EAIV) Delay time, ECLKOUTx high to EAx invalid
8 td(EKOxH-ADSV) Delay time, ECLKOUTx high to SADS/SRE valid
9 td(EKOxH-OEV) Delay time, ECLKOUTx high to, SOE validE
10 td(EKOxH-EDV) Delay time, ECLKOUTx high to EDx valid
11 td(EKOxH-EDIV) Delay time, ECLKOUTx high to EDx invalidE
12 td(EKOxH-WEV) Delay time, ECLKOUTx high to SWE valid
–50xEP
MIN MAX
1.3
6.4
6.4
1.3
6.4
1.3
1.3
6.4
1.3
6.4
6.4
1.3
1.3
6.4
UNIT
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
Submit Documentation Feedback
PARAMETER MEASUREMENT INFORMATION
59