English
Language : 

HD64336900G Datasheet, PDF (57/408 Pages) Renesas Technology Corp – 16-Bit Single-Chip Microcomputer H8 Family/H8/300H Tiny Series
Table 2.8 System Control Instructions
Instruction Size* Function
TRAPA
—
Starts trap-instruction exception handling.
RTE
—
Returns from an exception-handling routine.
SLEEP
—
Causes a transition to a power-down state.
LDC
B/W
(EAs) → CCR
Moves the source operand contents to the CCR. The CCR size is one
byte, but in transfer from memory, data is read by word access.
STC
B/W
CCR → (EAd), EXR → (EAd)
Transfers the CCR contents to a destination location. The condition code
register size is one byte, but in transfer to memory, data is written by
word access.
ANDC
B
CCR ∧ #IMM → CCR, EXR ∧ #IMM → EXR
Logically ANDs the CCR with immediate data.
ORC
B
CCR ∨ #IMM → CCR, EXR ∨ #IMM → EXR
Logically ORs the CCR with immediate data.
XORC
B
CCR ⊕ #IMM → CCR, EXR ⊕ #IMM → EXR
Logically XORs the CCR with immediate data.
NOP
—
PC + 2 → PC
Only increments the program counter.
Note: * Refers to the operand size.
B: Byte
W: Word
Table 2.9 Block Data Transfer Instructions
Instruction
EEPMOV.B
Size
—
EEPMOV.W —
Function
if R4L ≠ 0 then
Repeat @ER5+ → @ER6+,
R4L–1 → R4L
Until R4L = 0
else next;
if R4 ≠ 0 then
Repeat @ER5+ → @ER6+,
R4–1 → R4
Until R4 = 0
else next;
Transfers a data block. Starting from the address set in ER5, transfers
data for the number of bytes set in R4L or R4 to the address location set
in ER6.
Execution of the next instruction begins as soon as the transfer is
completed.
Rev. 1.00, 11/03, page 29 of 376