English
Language : 

PIC18F87J90 Datasheet, PDF (426/450 Pages) Microchip Technology – 64/80-Pin, High-Performance Microcontrollers with LCD Driver and nanoWatt Technology
PIC18F87J90 FAMILY
FIGURE 28-19: A/D CONVERSION TIMING
BSF ADCON0, GO
(Note 2)
131
Q4
130
A/D CLK
132
A/D DATA
9
8
7 ... ... 2
1
0
ADRES
ADIF
GO
SAMPLE
OLD_DATA
SAMPLING STOPPED
NEW_DATA
TCY (Note 1)
DONE
Note 1:
2:
If the A/D clock source is selected as RC, a time of TCY is added before the A/D clock starts. This allows the SLEEP instruction to
be executed.
This is a minimal RC delay (typically 100 ns), which also disconnects the holding capacitor from the analog input.
TABLE 28-25: A/D CONVERSION REQUIREMENTS
Param
No.
Symbol
Characteristic
Min Max Units
Conditions
130 TAD
A/D Clock Period
0.7 25.0(1) s TOSC based, VREF  3.0V
—
1
s A/D RC mode
131 TCNV Conversion Time
(not including acquisition time)(2)
11
12
TAD
132 TACQ Acquisition Time(3)
1.4
—
s -40C to +85C
135 TSWC Switching Time from Convert  Sample
— (Note 4)
136 TDIS Discharge Time
0.2
—
s
Note 1: The time of the A/D clock period is dependent on the device frequency and the TAD clock divider.
2: ADRES registers may be read on the following TCY cycle.
3: The time for the holding capacitor to acquire the “New” input voltage when the voltage changes full scale
after the conversion (VDD to VSS or VSS to VDD). The source impedance (RS) on the input channels is 50.
4: On the following cycle of the device clock.
DS39933D-page 426