English
Language : 

SE7210TP1-E Datasheet, PDF (100/145 Pages) Intel Corporation – Intel® Server Board Technical Product Specification
Intel® Server Board SE7210TP1-E TPS
Platform Management Architecture
Table 50: PEF Action Priorities
Action
Power-down
Soft shut-down
Power cycle
Reset
Diagnostic Interrupt
PET Alert
Sensor feedback
IPMB message event
Fault LED action
Identification LED action
Priority Delayed
1
Yes
2
Yes
Type
PEF Action
OEM PEF Action
3
Yes
PEF Action
4
Yes
PEF Action
5
No
PEF Action
6
No
PEF Action
7
No
OEM PEF Action
8
No
OEM PEF Action
9
No
OEM PEF Action
10
No
OEM PEF Action
Note
Not executed if a power-down action was
also selected.
Not executed if a power-down action was
also selected.
Not executed if a power-down action was
also selected.
Not executed if a power-down action was
also selected.
When selected, always occurs immediately
after detection of a critical event.
When selected, always occurs immediately
after detection of a critical event.
When selected, always occurs immediately
after detection of a critical event.
When selected, always occurs immediately
after detection of a critical event, and is
stopped after the de-assertion of all critical
events that requested LED blinking.
When selected, always occurs immediately
after detection of a critical event.
Table 51. National Semiconductor PC87431 integrated management controller Factory Default
Event Filters
Event Filter #
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
Non-critical
Non-critical
Critical
Critical
Critical
Critical
Critical
Critical
Degraded
Degraded
Degraded
Degraded
Critical
Critical
Non Critical
Non Critical
N/A
Offset Mask
Voltage Assert
Events
Voltage Deassert
Voltage Assert
Voltage Deassert
PS Soft Fail Assert
PS Soft Fail Deassert
Proc 1-2 Thermal Trip Assert
Proc 1-2 Thermal Trip, Config Error & IERR Deassert
Proc 1-2 FRB3 Assert
Proc 1-2 FRB3 Deassert
Proc 1-2 Hot Assert
Proc 1-2 Hot Deassert
FP NMI Assert
FP NMI Deassert
SCSI Terminator Fail Assert
SCSI Terminator Fail Deassert
ID Button Assert
86