English
Language : 

MB86613S Datasheet, PDF (31/134 Pages) Fujitsu Component Limited. – IEEE1394 Open HCI Controller
Preliminary
Bit
Field Name
rwu
---- -------------- ----
31:24 info_length
rw
23:16 crc_length
rw
15:0 rom_crc_value
rw
reset
--------
00h
description
------------------------------------------
Set the quadlet count of the bus_info_block included in
the 1394 configuration ROM.
00h
Set the 1394 configuration ROM byte count in quadlet unit.
0000h
Set the 1394 configuration ROM CRC.
3.2.6. Bus Identification
This register stores and indicates the first data of the bus_Info_block field in the 1934 configuration ROM (off-
set “FFFF_F000_0404h”).
31
24 23
16 15
87
0
busID
Bit
----
31:0
Field Name
rwu
-------------- ----
busID
r
reset
--------
3133 _
3934h
description
------------------------------------------
These bits indicate ”3133_3934h” which means the
”1394”d in ASCII code.
3.2.7. Bus Options
This register stores and indicates the second data of the bus_Info_block field in the 1934 configuration ROM
(off- set “FFFF_F000_0404h”). The max_rec field is available only when the HCControl.linkEnable bit is set.
If a packet, which has the transmission speed over the setting, is received, it is invalid.
31
24 23
16 15
87
0
max_rec
link_spd
Bit
Field Name
rwu
---- -------------- ----
15:12 max_rec
rw
2:0 link_spd
ru
reset
--------
*
description
------------------------------------------
These bits are used to specify the maximum byte count that
is possible for payloading at the block- write- request
packet receipt. *: ”512” is indicated at the hardware
reset state. For the software reset state, the current stored
data are indicated.
010b
Specify the link transfer rate.
As the maximum transfer rate is S400, Link_spd shows
”010b.”
30