MSCAN08 Controller (MSCAN08)
Programmer’s Model of Control Registers
Table 16-8. Time Segment Values
TSEG13 TSEG12 TSEG11 TSEG10
Time
Segment 1
TSEG22
0
0
0
0
1 Tq Cycle(1)
0
0
0
0
1
2 Tq Cycles(1)
0
0
0
1
0
3Tq Cycles(1)
.
0
0
1
1
4 Tq Cycles
.
.
.
.
.
.
1
.
.
.
.
.
1
1
1
1
16 Tq Cycles
1. This setting is not valid. Please refer to Table 16-4 for valid settings.
TSEG21
0
0
.
.
1
TSEG20
0
1
.
.
1
Time
Segment 2
1 Tq Cycle(1)
2 Tq Cycles
.
.
8Tq Cycles
16.13.5 MSCAN08 Receiver Flag Register (CRFLG)
All bits of this register are read and clear only. A flag can be cleared by writing a 1
to the corresponding bit position. A flag can be cleared only when the condition
which caused the setting is valid no more. Writing a 0 has no effect on the flag
setting. Every flag has an associated interrupt enable flag in the CRIER register. A
hard or soft reset will clear the register.
Address: $0504
Bit 7
6
5
4
3
2
1
Bit 0
Read:
Write:
WUPIF
RWRNIF TWRNIF
RERRIF
TERRIF
BOFFIF
OVRIF
RXF
Reset:
0
0
0
0
0
0
0
0
Figure 16-19. Receiver Flag Register (CRFLG)
WUPIF — Wakeup Interrupt Flag
If the MSCAN08 detects bus activity while in sleep mode, it sets the WUPIF flag.
If not masked, a wakeup interrupt is pending while this flag is set.
1 = MSCAN08 has detected activity on the bus and requested wakeup.
0 = No wakeup interrupt has occurred.
RWRNIF — Receiver Warning Interrupt Flag
This flag is set when the MSCAN08 goes into warning status due to the receive
error counter (REC) exceeding 96 and neither one of the error interrupt flags or
the bus-off interrupt flag is set(1). If not masked, an error interrupt is pending
while this flag is set.
1 = MSCAN08 has gone into receiver warning status.
0 = No receiver warning status has been reached.
1. Condition to set the flag: RWRNIF = (96 → REC) & RERRIF & TERRIF & BOFFIF
MC68HC908GZ8
Freescale Semiconductor
MSCAN08 Controller (MSCAN08)
Data Sheet