English
Language : 

DS617 Datasheet, PDF (19/88 Pages) Xilinx, Inc – MultiBoot Bitstream, Design Revision Storage
R
Platform Flash XL High-Density Configuration and Storage Device
Table 8: Factory Commands
Bus Write Operations(1)
Command
Phase
First
Second
Third
Final – 1
Final
...
Add. Data Add. Data Add. Data
Add. Data Add. Data
Blank Check
2
BA BCh BA CBh
–
–
...
–
–
–
–
BKA
Setup
2
or
80h WA1 D0h
–
–
...
–
–
–
–
WA(2)
Buffer Enhanced
Factory Program
Program/
Verify(3)
≥32
WA1 PD1 WA1 PD2 WA1 PD3
...
WA1 PD31 WA1 PD32
Exit
1
NOT
BA1(4)
X
–
–
–
–
...
–
–
–
–
Notes:
1. WA = Word Address in targeted bank, BKA = Bank Address, PD =Program Data, BA = Block Address, X = Don’t Care.
2. Any address within the bank can be used.
3. The Program/Verify phase can be executed any number of times as long as the data is to be programmed to the same block.
4. WA1 is the Start Address, NOT BA1 = Not Block Address of WA1.
Table 9: Electronic Signature Codes
Code
Manufacturer Code
Device Code
Locked
Block Protection
Unlocked
Locked and Locked-Down
Unlocked and Locked-Down
Configuration Register
Protection Register PR0 Lock
Factory Default
OTP Area Permanently Locked
Protection Register PR0
Protection Register PR1 through PR16 Lock
Protection Registers PR1–PR16
Address (h)
Bank Address + 000
Bank Address + 001
Block Address + 002
Bank Address + 005
Bank Address + 080
Bank Address + 081
Bank Address + 084
Bank Address + 085
Bank Address + 088
Bank Address + 089
Bank Address + 08A
Bank Address + 109
Data (h)
0049
506B
0001
0000
0003
0002
CR(1)
0002
0000
Unique Device Number
OTP Area
PRLD(1)
OTP Area
Notes:
1. CR = Configuration Register, PRLD = Protection Register Lock Data.
2. The iMPACT software does not support reading of the electronic signature codes.
DS617 (v3.0.1) January 07, 2010
www.xilinx.com
Product Specification
19