English
Language : 

SM320LF2407-EP Datasheet, PDF (57/112 Pages) Texas Instruments – DSP CONTROLLERS
SM320LF2407AĆEP
DSP CONTROLLERS
SGUS036B − JULY 2003 − REVISED OCTOBER 2003
LF240xA ELECTRICAL SPECIFICATIONS DATA
absolute maximum ratings over operating case temperature ranges (unless otherwise noted)†
Supply voltage range, VDD, PLLVCCA, VDDO, and VCCA (see Note 1) . . . . . . . . . . . . . . . . . . − 0.3 V to 4.6 V
VCCP range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . − 0.3 V to 5.5 V
Input voltage range, VIN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . − 0.3 V to 4.6 V
Output voltage range, VO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . − 0.3 V to 4.6 V
Input clamp current, IIK (VIN < 0 or VIN > VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 20 mA
Output clamp current, IOK (VO < 0 or VO > VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 20 mA
Operating case temperature ranges, TC: M version (see Notes 2 and 3) . . . . . . . . . . . . . − 55°C to 125°C
Junction temperature range, TJ (see Note 3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . − 55°C to 130°C
Storage temperature range, Tstg (see Note 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . − 65°C to 150°C
† Clamp current stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress
ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating
conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. All voltage values are with respect to VSS.
2. Long term high−temperature storage and/or extended use at maximum recommended operating conditions may result in a reduction
of overall device life. See http://www.ti.com/ep_quality for additional information on enhanced plastic packaging.
3. See the next section on device operating life for important information on temperature ranges.
device operating life
125°C case operating temperature denotes maximum test temperature only. Impact on estimated product life
from continuous operation of this device at elevated temperatures are shown in Figure 14 .
Bond (package) life is based on time-to-first failure due to intermetallic formation. After the first failure is
encountered, the failure rate approaches 100% in a very short time (a matter of months) due to the nature of
the failure mechanism.
Since the bond intermetallic life is a function of package components and temperature only, the 150°C point is
included to indicate the effect of extended high temperature storage.
Electromigration life is based on a FR50 of 50 FITS with an activation energy of 0.75 eV and follows a standard
wear-out curve.
• POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443
57