English
Language : 

MC68HC908AZ60 Datasheet, PDF (439/480 Pages) Motorola, Inc – HCMOS Microcontroller Unit
Specifications
Electrical Specifications
NOTES:
1. VDD = 5.0 Vdc ± 10%, VSS = 0 Vdc, TA = –40 °C to +TA(MAX), unless otherwise noted.
2. Run (Operating) IDD measured using external square wave clock source (fBUS = 8.4 MHz). All inputs
0.2 V from rail. No dc loads. Less than 100 pF on all outputs. CL = 20 pF on OSC2. All ports
configured as inputs. OSC2 capacitance linearly affects run IDD. Measured with all modules enabled.
3. Wait IDD measured using external square wave clock source (fBUS = 8.4 MHz). All inputs 0.2 Vdc
from rail. No dc loads. Less than 100 pF on all outputs, CL = 20 pF on OSC2. All ports configured
as inputs. OSC2 capacitance linearly affects wait IDD. Measured with all modules enabled.
4. Stop IDD measured with OSC1 = VSS.
5. Maximum is highest voltage that POR is guaranteed.
6. Maximum is highest voltage that POR is possible.
7. If minimum VDD is not reached before the internal POR reset is released, RST must be driven low
externally until minimum VDD is reached.
8. See COP Module During Break Interrupts on page 184.
9. Although IDD is proportional to bus frequency, a current of several mA is present even at very low
frequencies.
10. See Monitor Mode description within COP section. VHI applied to IRQ or RST.
5-specs
MOTOROLA
Specifications
MC68HC908AZ60 — Rev 2.0
437